Chillers, Air Cooled
-
Item# 168460
Chiller, 10 Ton, Air Cooled, Hydra NQ Series Rating At 50F Leaving Fluid Temperature At 95F Ambient. 460/60/3 Volt. Set Point Range 20F-80F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Includes Casters.Catalog Page 755
Instruction Manual
-
Item# 150186
Chiller, Air Cooled, Hydra Series 3 Ton, Rating At 50F Leaving Fluid Temperature At 95F Ambient. 460/60/3 Volt, Set Point Range 20F-65F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Casters Included.Catalog Page 755
Instruction Manual
-
Item# 168456
Chiller, 5 Ton, Air Cooled, Hydra NQ Series Rating At 50F Leaving Fluid Temperature At 95F Ambient. 460/60/3 Volt. Set Point Range 20F-80F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Includes Casters.Catalog Page 755
Instruction Manual
-
Item# 149622
Chiller, Air Cooled, Hydra Series 3 Ton, Rating At 50F Leaving Fluid Temperature At 95F Ambient. 230/60/3 Volt, Set Point Range 20F-65F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Casters Included.Catalog Page 755
Instruction Manual
-
Item# 168455
Chiller, 5 Ton, Air Cooled, Hydra NQ Series Rating At 50F Leaving Fluid Temperature At 95F Ambient. 230/60/3 Volt. Set Point Range 20F-80F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Includes Casters.Catalog Page 755
Instruction Manual
-
Item# 168813
Chiller, J Series, 4300 Btus/hr, 115/60/1, Rated At 65 Degree F. Water At 95 Degree F. Ambient, Includes Casters.Catalog Page 757
Instruction Manual
-
Item# 149621
Chiller, Air Cooled, Hydra Series 2 Ton, Rating At 50F Leaving Fluid Temperature At 95F Ambient. 460/60/3 Volt, Set Point Range 20F-65F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Casters Included.Catalog Page 755
Instruction Manual
-
Item# 168464
Chiller, 15 Ton, Air Cooled, Hydra NQ Series Rating At 50F Leaving Fluid Temperature At 95F Ambient. 460/60/3 Volt. Set Point Range 20F-80F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Includes Casters.Catalog Page 755
Instruction Manual
-
Item# 149620
Chiller, Air Cooled, Hydra Series 2 Ton, Rating At 50F Leaving Fluid Temp At 95F Ambient. 230/60/3 Volt, Set Point Range 20F-65F Complete with Digital Controls, Electronic Hot Gas Bypass, Stainless Steel Brazed Plate Evaporator, And Internal Valved Bypass Line To Protect The Pump And Evaporator. Y-Strainer Protects Evaporator From Contamination. Casters Included.Catalog Page 755
Instruction Manual
-
Item# 167990
Chiller, J Series, 18,000 Btu/hr, Air Cooled 65 Degree F. Water At 95 Degree F. Ambient, 230/60/1, Includes Auto Water Fill & CastersCatalog Page 757
Instruction Manual